Tripp Lite 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs

  • Brand : Tripp Lite
  • Product name : 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs
  • Product code : PDU3V51
  • GTIN (EAN/UPC) : 0037332181367
  • Category : Power Distribution Units (PDUs)
  • Data-sheet quality : created/standardized by Icecat
  • Product views : 34389
  • Info modified on : 26 Feb 2023 15:29:15
  • Product Brochure/Datasheet (0.4 MB)
  • Warranty: : 5-year limited warranty
  • Long product name Tripp Lite 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs :

    8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs

  • Tripp Lite 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs :

    The PDU3V51 8.6/12.6kW 3-Phase Vertical PDU Outlet Strip is a required accessory for Tripp Lite’s PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other 3-phase ATS PDUs that specify compatibility with this model. It’s ideal for high-density equipment racks in data centers and server rooms.

    When used with 208V ATS PDUs with a 35A input rating, the PDU3V51 supports up to 12.6kW total output with 20A maximum full balanced load per phase combination output bank (L1-L2, L2-L3, L3-L1). When used with 208V ATS PDUs with a 24A input rating, it supports up to 8.6kW total output with 13.9A maximum full balanced load per phase combination output bank.

    The 51 single-phase 12A C13 outlets receive power from the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations (L1-L2, L2-L3, L3-L1) throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers them. The 2.5-foot power cord with eight-position plug connects directly to the ATS PDU’s rear outlet.

    The PDU3V51’s rugged all-metal housing mounts in compatible racks in seconds with no tools needed. Vertical 0U installation reduces cable clutter and improves airflow through the rack to keep your equipment cool and functioning at its peak.

    Required Accessory for Select Tripp Lite ATS PDUs
    - Compatible with PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other select Tripp Lite 3-phase ATS PDUs
    - Ideal for high-density equipment racks in data centers and server rooms
    - Supports up to 12.6kW total output with 20A maximum per output bank when connected to 208V ATS PDUs with a 35A input rating
    - Supports up to 8.6kW total output with 13.9A maximum per output bank when connected to 208V ATS PDUs with a 24A input rating

    51 Interlaced C13 Outlets
    - Single-phase 12A C13 outlets balance loads by spreading connections across all phase combinations throughout the rack
    - Numbered and color-coded for easy identification of connected devices and which phase combination output bank powers them

    Installs Easily in 0U of Rack Space
    - Preinstalled mounting buttons for toolless vertical rack-mounting in compatible racks
    - Reduces cable clutter by locating outlets closer to connected devices
    - Improves airflow through the rack to keep equipment cool and functioning at its peak
    - Rugged all-metal housing designed to last a long time
    - 2.5 ft. power cord with 8-position plug that connects directly to ATS PDU

  • Short summary description Tripp Lite 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs :

    Tripp Lite 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs, Managed, 0U, Vertical, Metal, Black, 51 AC outlet(s)

  • Long summary description Tripp Lite 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs :

    Tripp Lite 8.6/12.6kW 3-Phase Vertical PDU Strip, 208V Outlets (51 C13), 0U Rack-Mount, Required Accessory for Select ATS PDUs. PDU types: Managed, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 51 AC outlet(s), AC outlet types: C13 coupler. Cable length: 0.7 m. Nominal input voltage: 200-240 V, Maximum current: 35 A, AC input frequency: 50 - 60 Hz. Width: 56.4 mm, Depth: 47.5 mm, Dimensions (WxDxH): 55 x 56 x 1600 mm

Specs
Design
PDU types Managed
Rack capacity 0U
Mounting Vertical
Housing material Metal
Product colour Black
Ports & interfaces
AC outlets quantity 51 AC outlet(s)
AC outlet types C13 coupler
Features
Cable length 0.7 m
Power
Nominal input voltage 200-240 V
AC input frequency 50 - 60 Hz
Maximum current 35 A
Nominal output voltage 200-240 V
Maximum input current per phase 20 A
Maximum power 12600 W
Weight & dimensions
Width 56.4 mm
Depth 47.5 mm
Dimensions (WxDxH) 55 x 56 x 1600 mm
Height 1600.2 mm
Weight 4.13 kg

Packaging data
Package dimensions (WxDxH) 180 x 150 x 1770 mm
Package weight 5.58 kg
Package width 167.6 mm
Package depth 1765.3 mm
Package height 132.1 mm
Operational conditions
Operating temperature (T-T) 0 - 50 °C
Storage temperature (T-T) -15 - 60 °C
Operating relative humidity (H-H) 5 - 95%
Technical details
Sustainability certificates RoHS
Master (outer) case GTIN (EAN/UPC) 10037332181364
Logistics data
Country of origin China
Master (outer) case width 373.4 mm
Master (outer) case length 1780.5 mm
Master (outer) case height 162.6 mm
Master (outer) case gross weight 12.8 kg
Products per master (outer) case 2 pc(s)
Similar products
Product code: PDU3V602D354B
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDU3V602D354A
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDU3V20D354A
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)